The YT-73090 clamp meter is equipped with clamps to measure alternating current in a single wire using the inductive method. This makes it possible to measure much higher currents than conventional electrical meters. The meter is a supplement to the universal meter YT-73085 and to any universal meter that measures in the millivolt range.
Basic measurements:
- AC current measurement: A.C. 0-600 A
Measurement accuracies:
Example of accuracy determination for AC current measurement. Calculation for the measurement result: 30 A
- The measurement accuracy of the YT-73090 meter for this range is: ±(2% + 0.5), resolution 1 A
- Calculation of the measurement error formula: (measurement result x 2%) + 0.5 x resolution
- calculation: (30 x 2%) + 0.5 x 1 = 0.6 + 0.5 = 1.10 A
Actual result including measurement error for an indication of 30 A = 30 ± 1.25 A.
A table with the resolution and accuracy for the measurement in question can be found in the manual.
Additional information:
- Clamps open up to 31 mm and make it possible to measure a single conductor with a maximum diameter of 20 mm
- 2-stage adjustment of the measurement range: up to 200 A and up to 600 A
- Includes carrying case and probes
Please note!
Current measurements with clamp meters are only carried out on a single conductor, a single cable. If you clamp the clamp meters on a cable with multiple conductors without isolating the single conductor, you will get an incorrect result or zero current.