With the YT-73092 universal current clamp meter with automatic range for most indications, basic and advanced electrical measurements can be performed. The meter is equipped with a clamp that allows AC current to be measured in a single wire using the inductive method. The measurement takes place without disconnecting the circuit or disconnecting it from the power source and makes it possible to measure much higher currents than with conventional electrical meters.
Basic measurements:
- AC voltage measurement: A.C. 0-600 V, TRUE RMS + V.F.C. + LowZ
- DC voltage measurement: DC 0-600 V, LowZ
- AC current measurement: A.C. 0-600 A, TRUE RMS + V.F.C.
- resistance measurement: 0-60 MΩ
- diode test:IF 1 mA,UR 2.3 V
- circuit continuity test: 0-120 Ω
Additional measurements:
- AC voltage measurement in low impedance mode: A.C. 0-600 V
- DC voltage measurement in low impedance mode: D.C. 0-600 V
- non-contact AC voltage detection: NCV
Measurement accuracies:
Example of accuracy determination for AC current measurement. Calculation for measurement result: 30 A
- The measurement accuracy of the YT-73092 meter for this range is: ±(2.5%+10), resolution 0.01 A
- Calculation of the measurement error formula: (measurement result x 2.5%) + 10 x resolution
- calculation: (30 x 2.5%) + 10 x 0.01 = 0.75 + 0.1 = 0.8 A
Actual result including measurement error for indication of 30 A = 30 ± 0.85 A
- result including measurement error for indication of AC voltage: 235 V = 235 ± 3.3 V
- result including measurement error for indication of DC voltage measurement 12 V = 12 ± 0.116 V
A table with the resolution and accuracy for the relevant measurement can be found in the manual.
Built-in functions:
- TRUE RMS - a meter with this function displays the actual rms value of the AC voltage/voltage. Unlike averaging meters, devices with true rms not only display the correct value for sine waves, but also for distorted sine waves, for example due to higher harmonics, or square or triangular waves. An indispensable function anywhere where switching power supplies, motor inverter drives, HVAC systems, etc. occur in a circuit.
- NCV - non-contact AC voltage detection by inductive method. The meter detects the presence of voltage in an isolated wire and can also indicate the phase wire.
- LowZ - AC and DC voltage measurement in low impedance mode. The phenomenon often called ghost voltage can complicate the diagnosis of power networks in, for example, industrial buildings. This phenomenon is caused by the voltage that appears on a disconnected cable in which voltage is induced from a cable connected to the power grid that runs through the same channel. The LowZ function reduces the impedance of the meter's measuring leads by a factor of 10 compared to the standard measurement mode, after which the meter draws a slightly higher current during voltage sampling and thus discharges the charge that has accumulated in the cable. The result is a voltage measurement without ghost voltage.
- V.F.C. Low-pass filter. This function is used, for example, when measuring the output voltage of an electric motor controller that uses frequency and voltage variation to control the motor speed (VFD controllers). When the function is activated, the meter filters out high-frequency interference from, for example, a PWM signal and only the low frequency remains. In this way, the filter makes an accurate measurement possible of the rms value of the voltage/current flowing into the motor.
- AUTO - automatic adjustment of the measurement range. When measuring unknown values with a meter with manual range adjustment with the button, the measurements must be performed sequentially from the largest range to the range that provides the most accurate result - otherwise you risk damaging the instrument. In the case of a multimeter with the AUTO function, however, it is sufficient to take one measurement and the meter will automatically find the optimal range. The meter starts in AUTO mode by default
- SEL - changes the measurement mode, e.g. from AC to DC voltage measurement, switching from diode test to circuit continuity test or resistance measurement
- HOLD - holds the current measured value on the display
Additional information
- LCD display, maximum displayed result: 5999
- screen backlight
- lighting of the clamp measurement field
- audio signal in the continuity test for resistances below 60 Ω
- ability to enable diode and continuity tests separately
- clamps open up to 26 mm and allow measurement of a single wire with max. diameter of 18 mm
- test probes and carrying bag included
- construction with overload protection
- automatic shutdown of the meter after 15 minutes of inactivity
- battery indicator
- power supply: two 1.5 V (AAA) batteries